Ascend Academic Supported Imaging Acquisition Devices

Legend

Windows Compatible
Mac Compatible

Supported Intraoral X-ray Acquisition Devices

  • Apteryx Tuxedo – supported using e2v as the acquisition device; previous versions supported using Hamamatsu as the acquisition device

Note: Tuxedo sensors that were manufactured prior to 2019 are Hamamatsu devices (LED Dental Tuxedo sensors), which are supported using Hamamatsu as the acquisition device. Contact LED Dental to verify if your Tuxedo sensor is a Hamamatsu or e2v device.

  • Brassler GEM
  • CARINA
  • Dentimax Dream  – supported using e2v as the acquisition device
  • Dentsply Sirona XIOS XG
  • Dentsply Sirona Xios AE and Schick AE  
  • EVA Select  – supported using e2v as the acquisition device
  • FTG DC-Air
  • Gendex/KaVo IO – supported using GxPicture as the acquisition device
  • Gendex Visualix GX-S – only compatible with Windows XP
  • ImageWorks EVA Select – supported directly as an e2v as the acquisition device or supported via a TWAIN driver
  • InstaRay  – supported using Hamamatsu as the acquisition device

  • Jazz Solo
  • KaVo IXS
  • Owandy ONE and OPTEO
  • Polaroid KEREN HD-S
  • QuickRay  – supported using e2v as the acquisition device
  • QuickRay HD  – supported using Hamamatsu as the acquisition device

  • Remedi – supported using Hamamatsu as the acquisition device

  • Schick AE (Dentsply Sirona)
  • SOTA Clio/Clio Prime  – supported using e2v as the acquisition device
  • Suni – most models supported via a TWAIN driver; contact Support department to verify

  • Teledyne e2v 

    Note: e2v sensors are rebranded and sold by many companies under their specific brand names. The following devices are supported using e2v as the acquisition device:

    • Dentimax Dream sensor
    • EVA Select sensor
    • SOTA Clio/Clio Prime sensor
    • Apteryx Tuxedo sensor (the older model is supported using Hamamatsu as the acquisition device)
    • QuickRay/InstaRay
    • XDR X-ray sensor
  • Vatech HD Sensor – supported via a TWAIN driver or Vatech EzDent-i Software Bridge

  • Vatech Wave Sensor – supported via a TWAIN driver or Vatech EzDent-i Software Bridge

  • XDR X-ray sensor  – supported using e2v as the acquisition device
  • Carestream Imaging Software Bridge

  • DTX Studio Software Bridge
  • J. Morita i-Dixel Software Bridge

Supported Phosphor Plate Devices

  • Acteon Sopro PSPIX
  • Air Techniques ScanX Classic
  • Air Techniques ScanX Duo 
  • Air Techniques ScanX IO
  • Air Techniques ScanX Swift
  • Durr VistaScan – supported directly or via a TWAIN driver
  • Durr VistaScan Combi+ – supported directly or via a TWAIN driver
  • Durr VistaScan Mini – supported directly or via a TWAIN driver
  • Durr VistaScan Perio – supported directly or via a TWAIN driver
  • Gendex Denoptix QST
  • Gendex GXPS-500
  • Instrumentarium Express
  • Instrumentarium Express Origo
  • KaVo Scan eXam
  • KaVo Scan eXam One
  • Soredex Digora Optime

Supported Extraoral X-ray Devices (Pan and Ceph)

  • Gendex Orthoralix 8500/9200 DDE
  • J. Morita Veraviewepocs 2D – supported via a TWAIN driver
  • J. Morita Veraviewepocs 3D Series – supported via a TWAIN driver or the i-Dixel software bridge
  • J. Mortia Veraview IC5 HD – supported via a TWAIN driver or the i-Dixel software bridge
  • J. Morita Veraview X800 – supported via a TWAIN driver or the i-Dixel software bridge
  • KaVo OP3D – supported via an Instrumentarium TWAIN 7.6 driver
  • Vatech PaX-i and Pax-i Plus – supported via a TWAIN driver or Vatech EzDent-i Software Bridge
  • Carestream Imaging Software Bridge
  • DTX Studio Software Bridge
  • J. Morita i-Dixel Software Bridge
  • Vatech EzDent-i Software Bridge

Supported Intraoral/Extraoral Color Devices

  • Carestream CS1000, CS1200, and CS1500 – supported via a TWAIN driver
  • Dexis CariVu
  • DiscoveryHD Lite (Wired)
  • DiscoveryHD Lite (Wireless)
  • MouthWatch – supported using the Generic Intraoral Camera device in Ascend Academic Imaging; MouthWatch Capture must be installed and configured
  • iPad – supported using one of the built-in cameras via the Safari browser on iOS
  • Any USB intraoral camera with buttons that has a joystick/game-port interface
  • Carestream Imaging Software Bridge
  • DTX Studio Software Bridge
  • J. Morita i-Dixel Software Bridge
  • Shadewave Software Bridge (browser-based, color-matching software)

Supported CAD/CAM Scan Devices

  • DTX Studio Software Bridge
  • Romexis Software Bridge
  • File Import (.stl, .ply)

Supported 3D Volume Devices (CBCT)

  • J. Morita Veraviewepocs 3D Series – supported via the i-Dixel software bridge
  • J. Morita Veraview X800 – supported via the i-Dixel software bridge
  • J. Morita 3D Accuitomo Series – supported via the i-Dixel software bridge
  • Carestream Imaging Software Bridge
  • DTX Studio Software Bridge
  • J. Morita i-Dixel Software Bridge
  • Romexis Software Bridge
  • Sidexis Software Bridge
  • Vatech EzDent-i Software Bridge
  • File Import (.dcm)

Important: If you want to use a device other than a DEXIS device, additional costs may be required, such as the purchase of drivers, to integrate that device with Ascend Academic Imaging. Before you purchase the Ascend Academic Imaging add-on or a particular device that you want to use with Ascend Academic Imaging, consult the manufacturer of that device to verify if there will be costs to get that device working with Ascend Academic Imaging.

Note: Some, but not all, devices have been testing using a TWAIN driver. Using a TWAIN driver with certain devices might have unexpected results.